Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız: http://hdl.handle.net/11452/24855
Başlık: Laparoscopic management of malfunctioning peritoneal dialysis catheters
Yazarlar: Uludağ Üniversitesi/Tıp Fakültesi/Cerrahi Bilimler Bölümü.
Yılmazlar, Tuncay
Yavuz, Mahmut
Ceylan, Hasan Hüseyin
6701800362
7006244754
57213447556
Anahtar kelimeler: Peritoneal dialysis
Catheter malfunction
Laparoscopy
Renal disease
Kidney
Placement
Videolaparoscopy
Tenckhoff
Yayın Tarihi: Ağu-2001
Yayıncı: Springer
Atıf: Yılmazlar, T. vd. (2002). "Laparoscopic management of malfunctioning peritoneal dialysis catheters". Surgical Endoscopy and Other Invervential Techniques, 15(8), 820-822.
Özet: Background: Continuous ambulatory peritoneal dialysis (CAPD) is an established alternative method to hemodialysis for treating end-stage renal disease patients. However, this method is associated with a significant number of complications, such as catheter malposition, omental wrapping, and infection. The purpose of this study was to determine the efficacy of laparoscopy in the treatment of malfunctioning CAPD catheters. Methods: Between November 1994 and June 1999, a total of 16 patients with CAPD underwent laparoscopy for the evaluation and management of CAPD catheter dysfunction. Two trocars (10-mm and 5-mm) were used. Recorded data included patient demographics, catheter implantation method, date of malfunction, cause of dysfunction, procedure performed, complications, and catheter outcome. Results: The primary etiology of dysfunction was omentum and/or small bowel wrapping with adhesions in eight cases, malpositioning in five cases, and infection in the remaining three cases. Adhesiolysis was performed in the eight cases with adhesions. In the five cases with malpositioning but no adhesions, the catheters were repositioned in the pelvic cavity. Two catheters had to be withdrawn because of infection. In one case with tunnel infection, the catheters were exchanged simultaneously. There was only one perioperative complication, consisting of temporary dialysate leakage. There were no mechanical or infection problems. The overall success rate of catheter function (> 30 days after laparoscopy) was 100%, except for two cases in which the catheters had to be removed. Conclusion: Laparoscopy is a highly effective and successful method for the evaluation and management of peritoneal dialysis catheter dysfunction.
Açıklama: Bu çalışma, 28 Mart-1 Nisan 2000 tarihleri arasında Atlanta[ABD]'da düzenlenen Annual Meeting of the Society of American Gastrointestinal Endoscopic Surgeons (SAGES)'da bildiri olarak sunulmuştur.
URI: https://doi.org/10.1007/s004640080008
https://link.springer.com/article/10.1007%2Fs004640080008
http://hdl.handle.net/11452/24855
ISSN: 0930-2794
Koleksiyonlarda Görünür:Scopus