Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/29628
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Encarnaçao, Pedro M.C.C. | - |
dc.contributor.author | Cortez, André F.V. | - |
dc.contributor.author | Neves, Pedro N.B. | - |
dc.contributor.author | Santos, Filomena P. | - |
dc.contributor.author | Trindade, Alexandre M.F. | - |
dc.contributor.author | Borges, F. I.G.M. | - |
dc.contributor.author | Conde, Carlos A.N. | - |
dc.date.accessioned | 2022-11-29T11:44:24Z | - |
dc.date.available | 2022-11-29T11:44:24Z | - |
dc.date.issued | 2016-04-27 | - |
dc.identifier.citation | Encarnaçao, P. M. C. C. vd. (2016). "Experimental Ion Mobility measurements in Ne-CO2 and CO2-N-2 mixtures". Journal of Instrumentation, 11. | en_US |
dc.identifier.issn | 1748-0221 | - |
dc.identifier.uri | https://doi.org/10.1088/1748-0221/11/05/P05005 | - |
dc.identifier.uri | https://iopscience.iop.org/article/10.1088/1748-0221/11/05/P05005 | - |
dc.identifier.uri | http://hdl.handle.net/11452/29628 | - |
dc.description.abstract | In this paper we present the experimental results for the mobility, K-0, of ions in neon-carbon dioxide (Ne-CO2) and carbon dioxide-nitrogen (CO2-N-2) gaseous mixtures for total pressures ranging from 8-12 Torr, reduced electric fields in the 10-25 Td range, at room temperature. Regarding the Ne-CO2 mixture only one peak was observed for CO2 concentrations above 25%, which has been identified as an ion originated in CO2, while below 25% of CO2 a second-small peak appears at the left side of the main peak, which has been attributed to impurities. The mobility values for the main peak range between 3.51 +/- 0.05 and 1.07 +/- 0.01 cm(2)V(-1)s(-1) in the 10%-99% interval of CO2, and from 4.61 +/- 0.19 to 3.00 +/- 0.09 cm(2)V(-1)s(-1) for the second peak observed (10%-25% of CO2). For the CO2-N-2, the time-of-arrival spectra displayed only one peak for CO2 concentrations above 10%, which was attributed to ions originated in CO2, namely CO2+ (CO2), with a second peak appearing for CO2 concentrations below 10%. This second peak, with higher mobility, was attributed to CO2+ ions. The mobility values of the main peak range between 2.11 +/- 0.04 and 1.10 +/- 0.03 cm(2)V(-1)s(-1) in the 1%-99% interval of CO2, while the second peak's from 2.26 +/- 0.02 and 1.95 +/- 0.04 cm(2)V(-1)s(-1) (1%-10% of CO2). The inverse of the mobility displays an aproximately linear dependence on the CO2 concentration in the mixture. | en_US |
dc.description.sponsorship | RD51 Collaboration/CERN, through the common project "Measurement and calculation of ion mobility of some gas mixtures of interest" | en_US |
dc.description.sponsorship | Portuguese Foundation for Science and Technology - SFRH/BD/52333/2013 | en_US |
dc.description.sponsorship | FEDER, through the Programa Operacional Factores de Competitividade - COMPETE | en_US |
dc.description.sponsorship | National funds through FCT-Fundacao para a Ciencia e Tecnologia - 4825 | en_US |
dc.language.iso | en | en_US |
dc.publisher | IOP Publishing | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.rights | Atıf Gayri Ticari Türetilemez 4.0 Uluslararası | tr_TR |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Instruments & instrumentation | en_US |
dc.subject | Charge transport and multiplication in gas | en_US |
dc.subject | Gaseous detectors Ionization and excitation processes | en_US |
dc.subject | Reaction-rate coefficient | en_US |
dc.subject | Cross-sections Ionization | en_US |
dc.subject | Neon | en_US |
dc.subject | Ion sources (positive ions, negative ions, electron cyclotron resonance (ECR), electron beam (EBIS)) | en_US |
dc.subject | Electric fields | en_US |
dc.subject | Ions | en_US |
dc.subject | Mixtures | en_US |
dc.subject | CO2 concentration | en_US |
dc.subject | Gaseous mixture | en_US |
dc.subject | Ion-mobility measurements | en_US |
dc.subject | Linear dependence | en_US |
dc.subject | Mobility value | en_US |
dc.subject | Ne-CO2 mixture | en_US |
dc.subject | Total pressure | en_US |
dc.subject | Carbon dioxide | en_US |
dc.title | Experimental Ion Mobility measurements in Ne-CO2 and CO2-N-2 mixtures | en_US |
dc.type | Article | en_US |
dc.identifier.wos | 000377851700028 | tr_TR |
dc.identifier.scopus | 2-s2.0-84969141526 | tr_TR |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Fen-Edebiyat Fakültesi/Fizik Bölümü. | tr_TR |
dc.identifier.volume | 11 | tr_TR |
dc.relation.journal | Journal of Instrumentation | en_US |
dc.contributor.buuauthor | Veenhof, Robert J. | - |
dc.relation.collaboration | Yurt dışı | tr_TR |
dc.relation.collaboration | Sanayi | tr_TR |
dc.subject.wos | Instruments & instrumentation | en_US |
dc.indexed.wos | SCIE | en_US |
dc.indexed.scopus | Scopus | en_US |
dc.wos.quartile | Q3 | en_US |
dc.contributor.scopusid | 6603742499 | tr_TR |
dc.subject.scopus | Gas; Neon; Carbon Tetrafluoride | en_US |
Appears in Collections: | Scopus Web of Science |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Veenhof_vd_2016pdf | 1.8 MB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License