Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/29591
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.date.accessioned | 2022-11-28T08:52:09Z | - |
dc.date.available | 2022-11-28T08:52:09Z | - |
dc.date.issued | 2015-12-17 | - |
dc.identifier.citation | Tan, F. vd. (2016). "Effects of geometrical parameters on the pressure drop for a modified cyclone separator". Chemical Engineering and Technology, 39(3), Special Issue, 576-581. | en_US |
dc.identifier.issn | 0930-7516 | - |
dc.identifier.issn | 1521-4125 | - |
dc.identifier.uri | https://doi.org/10.1002/ceat.201500182 | - |
dc.identifier.uri | https://onlinelibrary.wiley.com/doi/10.1002/ceat.201500182 | - |
dc.identifier.uri | http://hdl.handle.net/11452/29591 | - |
dc.description.abstract | Experimental results for a conventional cyclone and a modified cyclone with an adjustable vortex stopper are presented. The modified design is based on the idea of decreasing the surface friction by leaving a separation space between the cylindrical part and the vortex stopper. The measured pressure losses were compared for various exit pipe diameters, cylinder heights, cone bottom diameters, and inlet velocities for the conventional as well as for the modified design. The comparative studies indicate a similar behavior of the pressure loss coefficient for both cyclones. Additionally, the exit pipe diameter has a more significant effect on both cyclones compared to the other parameters. Increasing the length of the cyclone reduced the pressure losses for all cases examined. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Wiley-V C H | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Engineering | en_US |
dc.subject | Cyclone | en_US |
dc.subject | Pressure drop | en_US |
dc.subject | Separation techniques | en_US |
dc.subject | Swirl flow | en_US |
dc.subject | Vortex finder | en_US |
dc.subject | Collection efficiency | en_US |
dc.subject | Numerical-simulation | en_US |
dc.subject | Performance | en_US |
dc.subject | Flow | en_US |
dc.subject | Hydrocyclone | en_US |
dc.subject | Optimization | en_US |
dc.subject | Design | en_US |
dc.subject | Length | en_US |
dc.subject | Geometry | en_US |
dc.subject | Piping systems | en_US |
dc.subject | Storms | en_US |
dc.subject | Vortex flow | en_US |
dc.subject | Comparative studies | en_US |
dc.subject | Cylinder heights | en_US |
dc.subject | Modified designs | en_US |
dc.subject | Pressure loss coefficient | en_US |
dc.subject | Separation space | en_US |
dc.subject | Surface friction | en_US |
dc.subject | Drops | en_US |
dc.title | Effects of geometrical parameters on the pressure drop for a modified cyclone separator | en_US |
dc.type | Article | en_US |
dc.identifier.wos | 000372960900025 | tr_TR |
dc.identifier.scopus | 2-s2.0-84958882263 | tr_TR |
dc.relation.tubitak | 114M591 | tr_TR |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü. | tr_TR |
dc.identifier.startpage | 576 | tr_TR |
dc.identifier.endpage | 581 | tr_TR |
dc.identifier.volume | 39 | tr_TR |
dc.identifier.issue | 3, Special Issue | en_US |
dc.relation.journal | Chemical Engineering and Technology | en_US |
dc.contributor.buuauthor | Tan, Fuat | - |
dc.contributor.buuauthor | Karagöz, İrfan | - |
dc.contributor.buuauthor | Avcı, Atakan | - |
dc.contributor.researcherid | AAB-9388-2020 | tr_TR |
dc.subject.wos | Engineering, chemical | en_US |
dc.indexed.wos | SCIE | en_US |
dc.indexed.scopus | Scopus | en_US |
dc.wos.quartile | Q2 | en_US |
dc.contributor.scopusid | 57131310700 | tr_TR |
dc.contributor.scopusid | 56785809700 | tr_TR |
dc.contributor.scopusid | 7004169972 | tr_TR |
dc.subject.scopus | Cyclone Separators; Gas; Pressure Drop | en_US |
Appears in Collections: | Scopus Web of Science |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.