Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız:
http://hdl.handle.net/11452/26587
Tüm üstveri kaydı
Dublin Core Alanı | Değer | Dil |
---|---|---|
dc.contributor.author | Yalçın, Sezai | - |
dc.contributor.author | Gündoğdu, Özcan | - |
dc.contributor.author | Sharaf, Jamal M. | - |
dc.contributor.author | Bradley, David A. | - |
dc.date.accessioned | 2022-05-20T13:21:12Z | - |
dc.date.available | 2022-05-20T13:21:12Z | - |
dc.date.issued | 2012-07 | - |
dc.identifier.citation | Tarım, U. A. vd. (2012). "The energy spectrum of 662 keV photons in a water equivalent phantom". Radiation Physics and Chemistry, 81(7), 745-748. | en_US |
dc.identifier.issn | 0969-806X | - |
dc.identifier.uri | https://doi.org/10.1016/j.radphyschem.2012.03.019 | - |
dc.identifier.uri | https://www.sciencedirect.com/science/article/pii/S0969806X12001673 | - |
dc.identifier.uri | http://hdl.handle.net/11452/26587 | - |
dc.description.abstract | Investigation is made on the energy spectrum of photons originating from interactions of 662 key primary gamma-ray photons emitted by a point source positioned at the centre of a water equivalent solid phantom of dimensions 19 cm x 19 cm x 24 cm. Peaks resulting from total energy loss (photo-peak) and multiple and back scattering have been observed using a 51 mm x 51 mm Nal(TI) detector; good agreement being found between the measured and simulated response functions. The energy spectrum of the gamma photons obtained through the Monte Carlo simulation reveals local maxima at about 100 key and 210 keV, being also observed in the experimental response function. Such spectra can be used as a method of testing the water equivalence of solid phantom media before their use for dosimetry measurements. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Pergamon-Elsevier Science | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Chemistry | en_US |
dc.subject | Nuclear science & technology | en_US |
dc.subject | Physics | en_US |
dc.subject | Water equivalent phantom | en_US |
dc.subject | Monte carlo | en_US |
dc.subject | Transmitted photon spectrum | en_US |
dc.subject | Multiple-scattering | en_US |
dc.subject | Ray | en_US |
dc.subject | Compton | en_US |
dc.subject | Backscattering | en_US |
dc.subject | Energy dissipation | en_US |
dc.subject | Gamma rays | en_US |
dc.subject | Intelligent systems | en_US |
dc.subject | Monte carlo methods | en_US |
dc.subject | Photons | en_US |
dc.subject | Sodium Iodide | en_US |
dc.subject | Spectroscopy | en_US |
dc.subject | Dosimetry measurement | en_US |
dc.subject | Gamma-ray photons | en_US |
dc.subject | Response functions | en_US |
dc.subject | Simulated response | en_US |
dc.subject | Total energy loss | en_US |
dc.subject | Transmitted photon spectrums | en_US |
dc.subject | Water equivalence | en_US |
dc.subject | Water equivalent phantoms | en_US |
dc.subject | Phantoms | en_US |
dc.title | The energy spectrum of 662 keV photons in a water equivalent phantom | en_US |
dc.type | Article | en_US |
dc.identifier.wos | 000305656800005 | tr_TR |
dc.identifier.scopus | 2-s2.0-84861660959 | tr_TR |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Fen-Edebiyat Fakültesi/Fizik Bölümü. | tr_TR |
dc.identifier.startpage | 745 | tr_TR |
dc.identifier.endpage | 748 | tr_TR |
dc.identifier.volume | 81 | tr_TR |
dc.identifier.issue | 7 | tr_TR |
dc.relation.journal | Radiation Physics and Chemistry | en_US |
dc.contributor.buuauthor | Tarım, Urkiye Akar | - |
dc.contributor.buuauthor | Gürler, Orhan | - |
dc.contributor.buuauthor | Özmutlu, Emin N. | - |
dc.contributor.researcherid | AAH-4270-2021 | tr_TR |
dc.contributor.researcherid | AAH-1837-2021 | tr_TR |
dc.relation.collaboration | Yurt içi | tr_TR |
dc.relation.collaboration | Yurt dışı | tr_TR |
dc.subject.wos | Chemistry, physical | en_US |
dc.subject.wos | Nuclear science & technology | en_US |
dc.subject.wos | Physics, atomic, molecular & chemical | en_US |
dc.indexed.wos | SCIE | en_US |
dc.indexed.scopus | Scopus | en_US |
dc.wos.quartile | Q3 | en_US |
dc.wos.quartile | Q1 (Nuclear science & technology) | en_US |
dc.contributor.scopusid | 55062460600 | tr_TR |
dc.contributor.scopusid | 14019444500 | tr_TR |
dc.contributor.scopusid | 6507726213 | tr_TR |
dc.subject.scopus | Compton Scattering; Scatter; Scintillation Counters | en_US |
dc.subject.emtree | Article | en_US |
dc.subject.emtree | Gamma radiation | en_US |
dc.subject.emtree | Light scattering | en_US |
dc.subject.emtree | Monte carlo method | en_US |
dc.subject.emtree | Photon | en_US |
dc.subject.emtree | Radiation energy | en_US |
dc.subject.emtree | Radiological parameters | en_US |
dc.subject.emtree | Spectrum | en_US |
dc.subject.emtree | Water equivalent phantom | en_US |
Koleksiyonlarda Görünür: | Scopus Web of Science |
Bu öğenin dosyaları:
Bu öğeyle ilişkili dosya bulunmamaktadır.
DSpace'deki bütün öğeler, aksi belirtilmedikçe, tüm hakları saklı tutulmak şartıyla telif hakkı ile korunmaktadır.