Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız:
http://hdl.handle.net/11452/23066
Tüm üstveri kaydı
Dublin Core Alanı | Değer | Dil |
---|---|---|
dc.date.accessioned | 2021-12-08T06:39:36Z | - |
dc.date.available | 2021-12-08T06:39:36Z | - |
dc.date.issued | 2010-04 | - |
dc.identifier.citation | Peksöz, A. vd. (2010). "Giant magneto-impedance effect in diamagnetic organic thin film coated amorphous ribbons". Sensors and Actuators, A-Physical, 159(1), 69-72. | en_US |
dc.identifier.issn | 0924-4247 | - |
dc.identifier.uri | https://doi.org/10.1016/j.sna.2010.03.002 | - |
dc.identifier.uri | https://www.sciencedirect.com/science/article/pii/S0924424710001056 | - |
dc.identifier.uri | http://hdl.handle.net/11452/23066 | - |
dc.description.abstract | We grew a diamagnetic thin film on the surface of Co-based amorphous ribbon (Fe(5.85)Co(70.15)Mo(4)B(15)Si(5)) to investigate the effect of this coating on giant magneto-impedance (GM!). We investigated GMI over a frequency range of 0.1-3.0 MHz and under a static magnetic field. The results show that GMI for amorphous ribbons can be enhanced by this coating process. A changing in GMI as high as 90% was observed in diamagnetic organic thin film coated Co-based amorphous ribbons at 2 MHz. The very large enhancement of the GMI value is a consequence of the closed magnetic flux path under the organic film layer. In this work, we concentrated on enhancing the GMI effect. First, we show that sensitivities of the ribbons can be improved by using the coating technique. In addition, the surfaces of these samples were imaged and analyzed by an atomic force microscopy. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Science | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | GMI effect | en_US |
dc.subject | Amorphous ribbons | en_US |
dc.subject | Organic thin film | en_US |
dc.subject | Atomic force microscopy | en_US |
dc.subject | GMI | en_US |
dc.subject | Wires | en_US |
dc.subject | Complexes | en_US |
dc.subject | Sensor | en_US |
dc.subject | Ligand | en_US |
dc.subject | Field | en_US |
dc.subject | Engineering | en_US |
dc.subject | Instruments & instrumentation | en_US |
dc.subject | Atomic force microscopy | en_US |
dc.subject | Atoms | en_US |
dc.subject | Coatings | en_US |
dc.subject | Cobalt | en_US |
dc.subject | Electric impedance | en_US |
dc.subject | Magnetic fields | en_US |
dc.subject | Magnetic flux | en_US |
dc.subject | Magnetos | en_US |
dc.subject | Thin film devices | en_US |
dc.subject | Thin films | en_US |
dc.subject | Amorphous ribbon | en_US |
dc.subject | Coating process | en_US |
dc.subject | Frequency ranges | en_US |
dc.subject | Giant magneto impedance effect | en_US |
dc.subject | Giant magnetoimpedance | en_US |
dc.subject | GMI effects | en_US |
dc.subject | Organic films | en_US |
dc.subject | Organic thin films | en_US |
dc.subject | Static magnetic fields | en_US |
dc.subject | Amorphous films | en_US |
dc.title | Giant magneto-impedance effect in diamagnetic organic thin film coated amorphous ribbons | en_US |
dc.type | Article | en_US |
dc.identifier.wos | 000277661800010 | tr_TR |
dc.identifier.scopus | 2-s2.0-77950303624 | tr_TR |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Fen-Edebiyat Fakültesi/Kimya Bölümü. | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Fen-Edebiyat Fakültesi/Fizik Bölümü. | tr_TR |
dc.relation.bap | F-2009/29 | tr_TR |
dc.relation.bap | F-2009/44 | tr_TR |
dc.contributor.orcid | 0000-0003-2546-0022 | tr_TR |
dc.identifier.startpage | 69 | tr_TR |
dc.identifier.endpage | 72 | tr_TR |
dc.identifier.volume | 159 | tr_TR |
dc.identifier.issue | 1 | tr_TR |
dc.relation.journal | Sensors and Actuators A-Physical | en_US |
dc.contributor.buuauthor | Peksöz, Ahmet | - |
dc.contributor.buuauthor | Kaya, Yunus | - |
dc.contributor.buuauthor | Tayşioğlu, Aslı Ayten | - |
dc.contributor.buuauthor | Derebaşı, Naim | - |
dc.contributor.buuauthor | Kaynak, Gökay | - |
dc.contributor.researcherid | AAI-2254-2021 | tr_TR |
dc.contributor.researcherid | AAG-9772-2021 | tr_TR |
dc.identifier.pubmed | Pubmed numarası | en_US |
dc.subject.wos | Engineering, electrical & electronic | en_US |
dc.subject.wos | Instruments & instrumentation | en_US |
dc.indexed.wos | SCIE | en_US |
dc.indexed.scopus | Scopus | en_US |
dc.contributor.scopusid | 23100976500 | tr_TR |
dc.contributor.scopusid | 35181446100 | tr_TR |
dc.contributor.scopusid | 18038658800 | tr_TR |
dc.contributor.scopusid | 11540936300 | tr_TR |
dc.contributor.scopusid | 12042075600 | tr_TR |
dc.subject.scopus | Magnetic Sensors; Domain Walls; Ribbons | en_US |
Koleksiyonlarda Görünür: | Scopus Web of Science |
Bu öğenin dosyaları:
Bu öğeyle ilişkili dosya bulunmamaktadır.
DSpace'deki bütün öğeler, aksi belirtilmedikçe, tüm hakları saklı tutulmak şartıyla telif hakkı ile korunmaktadır.