Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/21116
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Vargas, José Viriato Coelho | - |
dc.contributor.author | Callander, T. M.S. | - |
dc.contributor.author | Fleming, John S. | - |
dc.contributor.author | Parise, José Alberto Reis | - |
dc.date.accessioned | 2021-07-06T08:50:16Z | - |
dc.date.available | 2021-07-06T08:50:16Z | - |
dc.date.issued | 1998 | - |
dc.identifier.citation | Vargas, J. V. C. vd. (1998). "Simulation of the transient response of heat driven refrigerators with continuous temperature control". International Journal of Refrigeration-Revue Internationale du Froid, 21(8), 648-660. | en_US |
dc.identifier.issn | 0140-7007 | - |
dc.identifier.uri | https://doi.org/10.1016/S0140-7007(98)00009-7 | - |
dc.identifier.uri | https://www.sciencedirect.com/science/article/pii/S0140700798000097 | - |
dc.identifier.uri | http://hdl.handle.net/11452/21116 | - |
dc.description.abstract | A theoretical and experimental study is presented and a mathematical model is introduced for a heat driven refrigeration system operating with continuous temperature control. The model consists of a refrigerated space, an absorption refrigerator, operating irreversibly, a temperature sensor and a reference signal, and a power law control action. The steady-state behavior of the absorption refrigerator model is validated by direct comparison between theoretical results and experimental data. The model is then used to identify an optimal thermal conductance allocation, for a fixed total thermal conductance inventory, such that the refrigeration rate is maximized and the 'pull-down' time is minimized. A simulation of the system operating in a transient mode is carried out to show that closed-loop operation results in a large reduction of fuel consumption, with respect to the 'on-off' operation. Appropriate dimensionless groups are identified and the generalized results reported in charts using dimensionless variables. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Science | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Thermodynamics | en_US |
dc.subject | Engineering | en_US |
dc.subject | Refrigerating system | en_US |
dc.subject | Absorption system | en_US |
dc.subject | Heat exchange | en_US |
dc.subject | Design | en_US |
dc.subject | Pump | en_US |
dc.title | Simulation of the transient response of heat driven refrigerators with continuous temperature control | en_US |
dc.type | Article | en_US |
dc.identifier.wos | 000077352200007 | tr_TR |
dc.identifier.scopus | 2-s2.0-0032304788 | tr_TR |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Bölümü. | tr_TR |
dc.contributor.orcid | 0000-0002-5519-8136 | tr_TR |
dc.identifier.startpage | 648 | tr_TR |
dc.identifier.endpage | 660 | tr_TR |
dc.identifier.volume | 21 | tr_TR |
dc.identifier.issue | 8 | tr_TR |
dc.relation.journal | International Journal of Refrigeration-Revue Internationale du Froid | en_US |
dc.contributor.buuauthor | Horuz, İlhami | - |
dc.contributor.researcherid | AAG-5647-2019 | tr_TR |
dc.relation.collaboration | Yurt dışı | tr_TR |
dc.subject.wos | Thermodynamics | en_US |
dc.subject.wos | Engineering, mechanical | en_US |
dc.indexed.wos | SCIE | en_US |
dc.indexed.scopus | Scopus | en_US |
dc.wos.quartile | Q2 (Engineering, mechanical) | en_US |
dc.wos.quartile | Q3 (Thermodynamics) | en_US |
Appears in Collections: | Web of Science |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.